Description
1.Simple operation with dual test circuits, tests both wrist straps and foot grounders.
2.Auto-ranging circuit automatically selects proper test range, user touches pad and LED displays test results. Red light and audible indicator mean circuit resistance is too high or too low.
3.It is complied with standard 6.1.3.3 in ANSI ESD S20.20.It is recommended to calibrate E0901 checker once year.
Specification
Operating Temperature | 0~31℃ |
Relative Humidity | 0~90% |
Size | 82.5mm(L)*39mm(H)*142.5mm(W) |
Weight | 235g |
Decay Test Results
Wrist test margin 750 KΩ ~10.5MΩ | Shoe cover test margin 750KΩ~10.5MΩ | ||
Resistance tolarance (±20%) | Test output | Resistance Tolerance (±20%) | Test output |
≤ 740KΩ | Red(FAIL LO) | ≤740KΩ | Red(FAIL LO) |
750KΩ | Green(PASS [Normal]) | 750KΩ | Green(PASS [Normal]) |
10.5MΩ | Green(PASS[Normal]) | 100MΩ | Green(PASS[Normal]) |
≥ 11.5MΩ | Red(FAIL HI[Fail Hi]) | ≥ 40MΩ | Red(FAIL HI[Fail Hi]) |
Application
1.Simple operation with dual test circuits, tests both wrist straps and foot grounders.
2.Auto-ranging circuit automatically selects proper test range, user touches pad and LED displays test results.
Package
by box first, then by carton
© Copyright 2021 SHENZHEN MAXSHARER TECHNOLOGY CO.,LTD, All Rights Reserved.粤ICP备11097083